## Parameters

<ParamField path="bandwidth" type="hertz" />

<ParamField path="common_mode_rejection_ratio" type="decibel" />

<ParamField path="gain_bandwidth_product" type="hertz" />

<ParamField path="input_bias_current" type="ampere" />

<ParamField path="input_offset_voltage" type="volt" />

<ParamField path="output_current" type="ampere" />

<ParamField path="slew_rate" type="volt / second" />

## Interfaces

<ParamField path="inverting_input" type="Electrical" />

<ParamField path="non_inverting_input" type="Electrical" />

<ParamField path="output" type="Electrical" />

<ParamField path="power" type="ElectricPower" />

## Global Attributes

These attributes are available to all modules and interfaces in a design.

<ParamField path="lcsc_id" type="str">
  Assign the LCSC ID of the module.

  If set, this will tell the picker to select that part from LCSC for this block.
</ParamField>

<ParamField path="manufacturer" type="str">
  This module's manufacturer name, as a string.

  Only exact matches on the manufacturer's name will be found by the picker.
  It's recommended to fill this information based on what `ato create component`
  provides.
</ParamField>

<ParamField path="mpn" type="str">
  This module's manufacturer part number, as a string.

  For the picker to select the correct part from the manufacturer,
  this must be set.
</ParamField>

<ParamField path="package" type="str">
  The package of the module.

  This drives which components can be selected, and what footprint is used.

  Must exactly match a known package name.
</ParamField>

<ParamField path="exclude_from_bom" type="bool" />

<ParamField path="override_net_name" type="str">
  When set on an interface, this will override the net name of the interface.

  This is useful for renaming nets which are automatically generated.
</ParamField>

<ParamField path="required" type="bool">
  Only for ModuleInterfaces.
  If set to `True`, require that interface is connected to something outside
  of the module it's defined in.
</ParamField>

<RequestExample>
  ```ato Basic Usage theme={null}
  import OpAmp, Resistor, ElectricPower, Electrical

  opamp = new OpAmp
  opamp.bandwidth = 1MHz +/- 10%
  opamp.gain_bandwidth_product = 10MHz +/- 20%
  opamp.input_offset_voltage = 1mV +/- 50%
  opamp.slew_rate = 1V/us +/- 20%
  opamp.package = "SOIC-8"

  # Power supply connections (dual supply)
  power_pos = new ElectricPower
  power_neg = new ElectricPower
  assert power_pos.voltage within 5V +/- 5%
  assert power_neg.voltage within -5V +/- 5%
  opamp.power.hv ~ power_pos.hv
  opamp.power.lv ~ power_neg.lv

  # Non-inverting amplifier configuration
  feedback_resistor = new Resistor
  gain_resistor = new Resistor
  feedback_resistor.resistance = 10kohm +/- 1%
  gain_resistor.resistance = 1kohm +/- 1%

  # Connections for gain = 1 + (Rf/Rg) = 11
  input_signal ~ opamp.non_inverting_input
  opamp.inverting_input ~> gain_resistor ~> power_neg.lv
  opamp.output ~> feedback_resistor ~> opamp.inverting_input
  output_signal ~ opamp.output
  ```
</RequestExample>